HighPROTEC MRA4

Feeder Protection

The MRA4 is a high precision and reliable protection and control relay. The intuitive setting concept with plausibility test enables reliable and time optimized configuration of the extensive protection function to a variety of applications such as incoming or outgoing feeder protection, network protection and generator protection.

Request offer

The MRA4 is a high precision and reliable protection and control relay. The intuitive setting concept with plausibility test enables reliable and time optimized configuration of the extensive protection function to a variety of applications such as incoming or outgoing feeder protection, network protection and generator protection.

The implemented switchgear management guaranties an efficient and safe control and supervision. The device is a bench mark in flexibility and usability and offers various communication options. The hardware is designed for all nominal values in combination with protection and control functionality.

The parameterizing and analyzing software Smart view SE is usable for each HighPROTEC device and free of charge.

Feature highlights

No items found.

Comprehensive Protection Package

  • Frequency measurement and ROCOF (af/dt) measurement is now user-adjustable. Further-more, measurement precision has been impro-ved: 5mHz from 45-55 Hz
  • 6 elements phase overcurrent protection directional and non-directional (ANSI/IEC/51C/51V)
  • Wattmetric Ground Fault Protection
  • 2 elements unbalanced load protection
  • Voltage protection (2)
 6 elements selectable: V<, V>, V<(t)
  • 6 elements unbalanced voltage supervision
  • Fourth Voltage measuring input (2)
 2 elements VE> or VX (for synchro-check)
  • Synchro-check options:
 Generator-to-System or System-to-System
  • 6 elements frequency protection;
 each can be used as: t>, f<, af/at (ROCOF), vector surge
  • 6 elements power protection;
  • each can be used as:
 P>, P<, Pr, Q>, Q<, Qr, S>, S<
  • PAV,E maximum power infeed
  • Two elements power factor (PF)

Interconnection package

The comprehensive interconnection package is summarized within one menu:

  • Non-discriminating active power direction depending load shedding
  • HVRT (High Voltage Ride Through)
  • FRT (LVRT): Settable FRI-Profiles, optional AR coordinated
  • QV-Protection: Undervoltage-Reactive
  • Power protection
  • Automatic Reconnection
  • Frequency protection:
 6 elements configurable as f<, f>, df/dt (ROCOF), vector surge
  • CB-Intertripping
  • Synchro-check Via Transformer

Recorders

  • Disturbance recorder: 120 s non volatile
  • Fault recorder: 20 faults
 Event recorder: 300 events
  • Trend recorder: 4000 non volatile entries

Demand Management/Peak Values

  • Peak values of current and power, average current and energy demand

Control

  • 1 breaker
  • Breaker wear

PC Tools

  • Setting and analyzing software
 Smart view free of charge
  • Including page editor to design own
 Control pages
  • SCADApter to re-assign datapoints for Retrofit projects: Modbus, Profibus,
 IEC 60870-5-103/-104

Power Quality

  • THD protectionr

Communication Options

  • IEC 61850
  • Profibus DP
  • Modbus RTU and/or Modbus TCP
  • IEC 60870-5-103/-104
  • DNP 3.0 (RTU, TCP, UDP)
  • SCADApter for Retrofit
  • Configurable SCADA protocols:
 Modbus, Profibus, IEC 60870-5-103/-104, DNP3
  • Redundant Ethernet: Two Ethernet channels available on the device [Electrical Ethernet [RJ45] 
or Optical Ethernet [FO] - fiber optic cable]

    • Switch-Mode [Redundancy with RSTP]

    • PRP - Parallel Redundancy Protocol

    • HSR - High-Availability Seamless Redundancy Protocol

Commissioning Support

  • Customizable Display (Single-Line)
  • Customizable Inserts
  • Copy and compare parameter sets
  • Configuration files are convertible
  • Forcing and disarming of output relays
  • Fault simulator: current, voltage
  • Graphical display of tripping characteristics
  • 8 languages selectable within the relay
  • USB Connection

Logic

  • Up to 80 logic equations for protection, control and monitoring

Time Synchronisation

  • SNTP, IRIG-BOOX, Modbus, DNP 3.0,
IEC 60870-5-103/-104

Cyber Security

  • Menu for the activation of BDEW-Whitepaper-compliant security settings
(e. g. hardening of interfaces)
  • Scurity Logger
  • Centralized Security Logs (Syslog)
  • Encrypted Connection Smart view Device
  • Device specific certificates (No man in the middle attacks)
  • Multi-Password-Level

Technical Specs

Connections (Example)

certified regarding
CSA-C22.2 No. 14


(Industrial Controls)

Type tested and certified by KEMA Laboratories in accordance with the complete type test requirements of IEC 60255‑1:2009.

certified by EAC


(Eurasian Conformity)

CE certified

VDE FNN compliant

Download
PDF files

All essential

HighPROTEC MRA4

information such as Broschures or User Manuals etc. are available in our download section.

Download PDF

Find your Contact Person

Do you need technical Support, or would you like to reach out to a Sales representative or someone from another department? Click the corresponding button here to display your relevant contact person:

Jens Schürmanns

Haben Sie Fragen?

Jens Schürmanns

Customer Account Manager

E-Mail
Thomas Hafermann

Haben Sie Fragen?

Thomas Hafermann

Senior Customer Account Manager

E-Mail
Thomas Schütt

Haben Sie Fragen?

Thomas Schütt

Customer Account Manager

E-Mail
Brenda Brown

Haben Sie Fragen?

Brenda Brown

Global Strategic Account Manager, Americas

E-Mail
Jose Rossano

Haben Sie Fragen?

Jose Rossano

Sales Manager

E-Mail
Kerelos Youssef

Haben Sie Fragen?

Kerelos Youssef

Customer Account Manager

E-Mail

Do you have questions?

Thomas Angenvoort

Sales Support Engineer

Email

Do you have questions?

Ronny Stelter

Technical Support Engineer

Email

Do you have questions?

Massimo Citzia

Sales Support Engineer

Email

Do you have questions?

Timo Keiper

HR Manager

Email

Do you have questions?

Dave Leverenz

Marketing Manager

Email

Do you have questions?

Jenny Dethlefsen

Executive Administrative Assistant

Email