HighPROTEC MRU4

Voltage Protection

The MRU4 is a protection relay which uses the latest Dual-Core-Processor Technology to provide precise and reliable protective functions and is very easy to operate.

It is designed to protect electrical equipment from dangerous voltage fluctuations. For example protection against under voltages caused by mains shortcircuits, or overvol-tages due to load shedding or failure of a generator voltage controller.

Request offer

The MRU4 is a protection relay which uses the latest Dual-Core-Processor Technology to provide precise and reliable protective functions and is very easy to operate.

It is designed to protect electrical equipment from dangerous voltage fluctuations. For example protection against under voltages caused by mains shortcircuits, or overvol-tages due to load shedding or failure of a generator voltage controller.

Its compact design makes the MRU4 ideal for installation within the LV terminal compartments of compact SF6-insulated MV systems.

The protection functions of the MRU4 have been adapted to comply with the requirements of the VDE-AR-N 4110: 2023-09.

Feature highlights

Approved

Marine Approvals

LR - Lloyd’s Register

All Inclusive

  • All protection features without extra charge
  • Parameter setting and evaluation software
  • Disturbance record analysis software

Comprehensive frequency protection packageEach of the six elements can be used as:

  • f< or f> (over- and underfrequency supervision)
  • df/dt (ROCOF) - Rate of change of frequency
  • (f< and df/dt) or (f> and df/dt) Combination of over-, under- and rate of change of frequency (ROCOF)
  • (f< and DF/DT) or (f> and DF/DT) Combination of over-, under-and increase of frequency
  • Delta Phi (Vector surge)

Six Elements Voltage Protection

  • Under- and overvoltage
  • Programmable time dependent undervoltage tripping characteristic

Six Elements Voltage Asymmetry Supervision

  • Under- and overvoltage in positive phase sequence system, overvoltage in negative phase sequence system

Logic

  • Up to 80 logic equations for protection, control and monitoring

Additional Highlights

  • Two Elements Residual Voltage Protection VE>
  • Flexible Fourth Voltage measuring input 2 elements VE > or VX (for Synchrocheck)
  • Sliding-Mean-Square Supervision, adjustable (VDE-AR 4105)
  • FRT (LVRT), adjustable LVRT-profiles, optionally
 AR-controlled
  • Synchrocheck, now via Transformer

Supervision

  • Voltage transformer supervision
  • Trip circuit supervision
  • CBF via position indicators

Recorders

  • Disturbance recorder: 120 s non volatile
  • Fault recorder: 20 faults non volatile
  • Event recorder: 300 events non volatile
  • Trend recorder: 4000 non volatile entries

Communication Options

  • IEC 61850
  • Profibus DP
  • Modbus RTU and/or Modbus TCP
  • IEC 60870-5-103/-104
  • DNP 3.0 (RTU, TCP, UDP)
  • SCADApter for Retrofit
  • Configurable SCADA protocols:
 Modbus, Profibus, IEC 60870-5-103/-104, DNP3
  • TypeCodes Communication O,P,Q,R
  • Redundant Ethernet: Two Ethernet channels available on the device [Electrical Ethernet [RJ45] or Optical Ethernet [FO] - fiber optic cable 

    • Switch-Mode [Redundancy with RSTP]

    • PRP - Parallel Redundancy Protocol

    • HSR - High-Availability Seamless Redundancy Protocol

Control

  • 1 breaker
  • Breaker wearr

Commissioning Support

  • Customizable Display (Single-Line)
  • Customizable Inserts
  • Copy and compare parameter sets
  • Configuration files are convertible
  • Forcing and disarming of output relays
  • Fault simulator: current, voltage
  • Graphical display of tripping characteristics
  • 8 languages selectable within the relay

PC Tools

  • Setting and analyzing software
 Smart view free of charge
  • Including page editor to design own
 Control pages
  • SCADApter to re-assign datapoints for Retrofit projects: Modbus, Profibus,
 IEC 60870-5-103/ -104

Cyber Security

  • Menu for the activation of BDEW Whitepaper-compliant security settings
(e. g. hardening of interfaces)
  • Security Logger
  • Centralized Security Logs (Syslog)
  • Encrypted Connection Smart view Device
  • Device specific certificates (No man in the middle attacks)
  • Multi-Password-Level

Time Synchronisation

  • SNTP, IRIG-BOOX, Modbus, DNP 3.0,
IEC 60870-5-103/-104

Technical Specs

Connections (Example)

certified regarding
CSA-C22.2 No. 14


(Industrial Controls)

Type tested and certified by KEMA Laboratories in accordance with the complete type test requirements of IEC 60255‑1:2009.

certified by EAC


(Eurasian Conformity)

certified regarding UL508


(Industrial Controls)

CE certified

VDE FNN compliant

Download
PDF files

All essential

HighPROTEC MRU4

information such as Broschures or User Manuals etc. are available in our download section.

Download PDF

Find your Contact Person

Do you need technical Support, or would you like to reach out to a Sales representative or someone from another department? Click the corresponding button here to display your relevant contact person:

Jens Schürmanns

Haben Sie Fragen?

Jens Schürmanns

Customer Account Manager

E-Mail
Thomas Hafermann

Haben Sie Fragen?

Thomas Hafermann

Senior Customer Account Manager

E-Mail
Thomas Schütt

Haben Sie Fragen?

Thomas Schütt

Customer Account Manager

E-Mail
Brenda Brown

Haben Sie Fragen?

Brenda Brown

Global Strategic Account Manager, Americas

E-Mail
Jose Rossano

Haben Sie Fragen?

Jose Rossano

Sales Manager

E-Mail
Kerelos Youssef

Haben Sie Fragen?

Kerelos Youssef

Customer Account Manager

E-Mail

Do you have questions?

Thomas Angenvoort

Sales Support Engineer

Email

Do you have questions?

Ronny Stelter

Technical Support Engineer

Email

Do you have questions?

Massimo Citzia

Sales Support Engineer

Email

Do you have questions?

Timo Keiper

HR Manager

Email

Do you have questions?

Dave Leverenz

Marketing Manager

Email

Do you have questions?

Jenny Dethlefsen

Executive Administrative Assistant

Email